Foster Manual Socket (Reusable Hose Clamp)

Brand
Foster U.S.A.

DESCRIPTIONS
One Way Shut Off: Coupler is valved, shutting of supply line at disconnect. Plug is unvalved, exhausting downstream lin at disconnect. Always install coupler on pressure side of line.

Intechangeability: Standard industrial design, 3 and 5 series Automatic water service comply with A-A-59439. 3,4,5,6 series meet ISO 6150-B, Ansi(NFPA)T3.20.14-1990. SV couplers meet ISO 4414.

Temperature range: -400F to 2250F

Seal Components: Buna-N seal compound. Other seals available on request.

Working Pressure: 300 psi; Vacuum to 26″Hg (connected)

 

Description

Manual
Manual sockets require manual retraction of sleeve to both connect and disconnect the plug.
  • low cost
  • positive locking mechanism
  • 65% more ball retention
  • precision leakproof seal
  • heavy steel sleeve
Automatic
Automatic sockets accept the plug by simple insertion without the need to retract the sleeve to connect.
  • one hand operation
  • one piece sleeve with rear crimp
  •  precision leakproof seal
  • long wearing pin type locking mechanism with greater plug
Safety
Sleeve is moved straight forward to lock and turn on the air. The sleeve is moved back by rotating first to the left then to the right.
  • 100% safety
  • connect and disconnect at zero pressure
  • plug is securely locked before air is turned on
  • downstream line is exhausted before plug is release
  • tested to 100,000 operations with no leakage
  • special lubrication eliminates dry breakaway
  • can be used as 3 way on-off valve without disconnecting

*** Do note that special request and MOQ are required for most parts.

 

Part No. Body Size Series Hose Size (ID X OD) Material Working Pressure (PSIG) Flow Rate @ 100PSI Weight/ PC (lbs)
SB3-3 1/4″ 3 Series 1/4″ X 1/2″ Steel 300 36 CFM 0.2722
SBS-3SS 1/4″ 3 Series 1/4″ X 1/2″ 303 SS 300 36 CFM 0.2762
SB5-3 1/4″ 3 Series 1/4″ X 9/16″ Steel 300 36 CFM 0.2996
SB7-3 1/4″ 3 Series 1/4″ X 9/16″ Steel 300 36 CFM 0.2864
SB7-3SS 1/4″ 3 Series 1/4″ X 5/8″ 303 SS 300 36 CFM 0.2669
SB9-3 1/4″ 3 Series 1/4″ X 11/16″ Steel 300 36 CFM
SC5-3 1/4″ 3 Series 5/15″ X 9/16″ Steel 300 36 CFM 0.3097
SC7-3 1/4″ 3 Series 5/16″ X 5/8″ Steel 300 36 CFM 0.2952
SD7-3 1/4″ 3 Series 3/8″ X 5/8″ Steel 300 36 CFM 0.3025
SD9-3 1/4″ 3 Series 3/8″ X 11/16″ Steel 300 36 CFM 0.3089
SD11-3 1/4″ 3 Series 3/8″ X 3/4″ Steel 300 36 CFM 0.3169
SD13-3 1/4″ 3 Series 3/8″ X 13/16″ Steel 300 36 CFM 0.3329
SB3-4 3/8″ 4 Series 1/4″ X 1/2″ Steel 300 68 CFM 0.3758
SB5-4 3/8″ 4 Series 1/4″ X 9/16″ Steel 300 68 CFM 0.4029
SB7-4 3/8″ 4 Series 1/4″ X 5/8″ Steel 300 68 CFM 0.3898
SB9-4 3/8″ 4 Series 1/4″ X 11/16″ Steel 300 68 CFM
SD7-4 3/8″ 4 Series 3/8″ X 5/8″ Steel 300 68 CFM 0.4106
SD9-4 3/8″ 4 Series 3/8″ X 11/16″ Steel 300 68 CFM 0.4188
SD11-4 3/8″ 4 Series 3/8″ X 3/4″ Steel 300 68 CFM 0.4251
SD13-4 3/8″ 4 Series 3/8″ X 13/16″ Steel 300 68 CFM 0.4427
SD7-5 1/2″ 5 Series 3/8″ X 5/8″ Steel 300 118 CFM 0.4976
SD9-5 1/2″ 5 Series 3/8″ X 11/16″ Steel 300 118 CFM 0.5061
SD11-5 1/2″ 5 Series 3/8″ X 3/4″ Steel 300 118 CFM 0.5122
SD13-5 1/2″ 5 Series 3/8″ X 13/16″ Steel 300 118 CFM 0.5304
SP13-5 1/2″ 5 Series 1/2″ X 7/8″ Steel 300 118 CFM 0.5654
SP15-5 1/2″ 5 Series 1/2″ X 7/8″ Steel 300 118 CFM 0.5773
SP17-5 1/2″ 5 Series 1/2″ X 15/16″ Steel 300 118 CFM 0.5907
SP19-5 1/2″ 5 Series 1/2″ X 1″ Steel 300 118 CFM 0.6684

Add-ons:

  1. BL option – Locks manual socket against accidental disconnect. To order, prefix ‘BL’ to part number.
  2. SL option – Locks automatic socket against accidental disconnect. To order, change FM to prefix to ‘SL’.

 

Didn’t find what you need? Please discuss your requirements with any of our Sales representatives.